Defining inputs and outputs for N507 Net Bridge

This section describes how to define inputs and outputs for an N507 Net Bridge in iLOQ 5 Series Manager.

The Net Bridge N507 can be configured as a stand-alone I/O card to operate a door with direct calendar controls or input controls.

Proceed as follows.

  1. Select Administration > Browse network modules.

  2. Select the desired N507 Net Bridge.
  3. Right-click to select Properties.
  4. Open the Devices tab.
  5. Select the IO module.
  6. Right-click to select Edit I/O controls.

    The Modify network module I/O controls wizard is opened.

  7. Select Edit.
  8. Select either Relays 1X10 or Relays 1X20.
  9. From the left, select the desired input number and output number.

    Here, you define the relations between inputs and outputs. One input can command several outputs, if needed.

    Also, give a name for the output, and select the Mode and Operating time for the relay.

    See Preparing N500 Net Bridges.

  10. Click Ready.

Can’t find what you are looking for?

Please note that iLOQ does not manage its customers' iLOQ locking systems.