Operation Mode 5
This operation mode is intended for using the iLOQ NFC Reader lights to illustrate the status of some customer system/device, while at the same time controlling a device with the relay K1.
An example use case is a building where an alarm system is controlled by the NFC Reader. A valid key activates the impulse for relay output K1 that is connected to the alarm system. Connect the alarm system status information to the door module IN1 to control LED A, and/or IN2 to control LED B. The status information you bring from the alarm system must be potential-free. If you have connected IN2, you can request for the alarm status information through the iLOQ Manager and view the event log on the alarm status.
In this case, the Door Module is programmed.
The table below describes the inputs controlling outputs K1 and K2 and whether the outputs are calendar controllable, and if alarm status can be transferred to the iLOQ Manager.
| K1 | K2 | LED A – GREEN | LED A – RED | ||
|---|---|---|---|---|---|
| Reader | X | ||||
| L1 | |||||
| L2 | |||||
| IN1 | X | ||||
| IN2 | X | ||||
| Calendar | X |
You can deploy this installation according to the instructions in Controlling Alarm Systems with RFID Readers. However, set the iLOQ N502 Online Door Module OPTIONS DIP switches as shown in the picture.
| S1 | OFF |
| S2 | ON |
| S3 | OFF |
| S4 | OFF |
| S5 | OFF |
- PreviousOperation Mode 4