Connecting Remotely Controlled Lock Cylinders
This section describes how to connect a lock cylinder to enable remote control.
- Make sure that the
switch on Net Bridge is set to STANDBY.
- Connect the Door Module to the prepared Net Bridge, or continue the bus from the last device on the main bus in accordance with the wiring diagram in iLOQ Online – Design Guide.
Note:
If you are continuing the bus from another bus device, remember to remove the bus termination (TERMINATION = OFF) from the device from which you are continuing the bus.
- Connect a programmed lock cylinder to the Door Module’s CYLINDERS L1 or L2 connector in accordance with the connection instructions.
- Set Operation Mode 1 by using the OPTIONS switches as follows:
S1 |
ON |
S2 |
ON |
S3 |
OFF |
S4 |
OFF |
- Set TERMINATION (TE/TEST) to ON if this bus device is the last device in this bus branch. If not, set it to OFF.
- After connecting the remaining bus devices, complete the Net Bridge settings once (see Completing the Bus Device Configuration on Net Bridge) and continue this procedure.
- In iLOQ 5 Series Manager, check that the lock no longer has an orange background colour in the lock grid view. Remember to refresh the grid view by pressing the F5 key.