Select your region or visit global site

Support
Open navigation

Bus Addresses and Termination

Each device connected to the main bus must have its own, unique bus address. Net Bridge only has one main bus, even if it is branched. Net Bridge automatically distributes bus addresses. If you have a device that has manual address dip switches, you can ignore them.

Terminate the last device on the bus or on the branch if the bus does not continue to the next device, by setting the TERMINATION dip to the ON position. If there are several branches on the bus, terminate the last device on each branch.

Was this article helpful?

That’s Great!

Thank you for your feedback

Sorry! We couldn't be helpful

Thank you for your feedback

Let us know how can we improve this article!

Select at least one of the reasons
CAPTCHA verification is required.

Feedback sent

We appreciate your effort and will try to fix the article

Didn't find what you were looking for?

Submit a ticket