Connecting a Remotely Managed Lock Cylinder

his section describes how to connect a lock cylinder to be remotely managed.

Proceed as follows.

  1. Ensure that the Net Bridge  switch is on STANDBY.
  2. Connect Door Module to a prepared Net Bridge, or continue the bus from the last connected bus device, according to the connection diagram in iLOQ S10 Online System - Planning Guidelines.
    Note:

    If you continue the bus from another bus device, remember to disable the termination (TERMINATION = OFF) from the device from which you continue the bus.

  3. Connect a programmed lock cylinder to the CYLINDERS L1 or L2 connector on the Door Module, according to the connection instructions.
  4. Set the operation mode 2 by the OPTIONS dip switches as follows:
    S1ON
    S2ON
    S3OFF
    S4OFF
    S5OFF
  5. Set the TERMINATION (TERM) dip switch to the ON position, if this bus device will be the last device on this bus branch. Otherwise, set it OFF.
  6. When you have also connected the other bus devices, finalize the Net Bridge configuration once (see Finalizing the Bus Device Configuration on Net Bridge) and continue this procedure.
  7. On iLOQ Manager software, check that the orange background color for the lock has disappeared from the lock grid view. Remember to refresh the grid view by pressing F5.


Was this article helpful?

That’s Great!

Thank you for your feedback

Sorry! We couldn't be helpful

Thank you for your feedback

Let us know how can we improve this article!

Select at least one of the reasons
CAPTCHA verification is required.

Feedback sent

We appreciate your effort and will try to fix the article

Didn't find what you were looking for?

Submit a ticket